GE KRAUT KRAMER DA590, 113-534-769 High Temperature Ultrasonic Thickness Probe
This probe is used for material thickness measurements in high-temperature environments. It is commonly used in industries such as energy, petrochemical, and metallurgy for inspecting pipes, tanks, and other equipment.
You can become a member here to see prices and take advantage of other privileges.
The DA590 operates at 5 MHz and can measure thicknesses ranging from 1.0 mm to 125 mm in steel at 20°C. It is designed for high-temperature applications and requires the C-120 or C-123 cable for operation.
Frequency: 5 MHz
Measurement Range: 1.0 mm - 125 mm (steel at 20°C)
High-Temperature Measurement Range: 1.3 mm - 25.4 mm (steel at 200°C)
Connector: Requires C-120 or C-123 cable