PARKER IPC704 signal conditioner

  • Vibration and dynamic pressure monitoring
  • Machinery health and structural analysis
  • Harsh industrial environments
  • Hazardous areas (ATEX/IECEx certified)
  • You can become a member here to see prices and take advantage of other privileges.
  • Converts sensor charge to 4–20 mA (2-wire) or 0–10 V (3-wire)
  • Frequency range: 0.5 Hz – 20 kHz
  • Optional velocity output via integrator
  • Adjustable high/low-pass filters
  • Long-distance transmission up to 1 km
  • RFI protection
  • Die-cast aluminum housing, optional IP66 enclosure
  • Supply: 18–30 V DC, max 25 mA
  • Operating temp: −30 … +85 °C
  • Protection: IP40 standard, IP66 optional
  • Vibration: 2 g (10–500 Hz), shock: 15 g (11 ms)
  • Certifications: ATEX/IECEx Ex ib IIC T6–T4
  • Input sensitivity: 0.1–10 mV/pC (standard), 0.1–50 mV/pC (GaPO₄)
  • Accuracy: ≤ 0.2 %, temp coefficient: ~100 ppm/°C