Capacity range: 50, 100, 200, 300, 500 kN Combined error: ±0.03 %Repeatability: ±0.01 %Safe overload: 200% (150% for 300 kN & 500 kN)Ultimate overload: 300% (200% for 300 kN & 500 kN) Side load tolerance: safe 100%, ultimate 200%Excitation voltage: recommended 10 V DC/AC, max 18 V DC/AC Input/output resistance: 350 Ω ±3 / ±0.5 Rated output: 2.040 mV/V ±0.1 %Zero balance: ±1 %Creep (30 mins): ±0.04 %Temp effect on zero: ±0.003 %/°CTemp effect on output: ±0.0015 %/°C Protection class: IP67Operating temp: −40 … +80 °C (up to +100 °C optional) Material: stainless steel for 50 kN; stainless or yellow chromate steel for 100–500 kN